Standard Rating : 1.5-20 AMPERE
Input Power : 125 VAC / 250 VAC /32 VDC
Dielectric Strength : 1500VAC / 1 Minute.
Interrupt Capacity : 125 VAC x 1000A, 250 VAC x 200A.
Insulation Resistance : >100 M?G[
Calibration :
25°C - 105% of Rated Current - Continuously Carried.
25°C - Between 101% to 134%-May Trip or Not.
25°C - 135% of Rated Current -Trip Within 1Hour.
25°C - 200% of Rated Current -Trip Within 1Minute.
Approval:
2-18A 125 / 250 VAC
3A-15A 125VAC
2A-15A 125VAC / 250VAC / 32VDC
Contact Endurance : 125 VAC x 150% of Rated Current -500 Cycles.
Reset : Manual Push Reset / Auto Reset.
Maximum Internal Resistance
|
Amp |
Ohm |
|
|
1.5A-2A |
|
|
|
2.5A-3A |
0.012 |
|
|
3.1A-4A |
0.080 |
|
|
4.1A-5A |
0.040 |
|
|
5.1A-6A |
0.025 |
|
|
6.1A-7A |
0.020 |
|
|
8.1A-9A |
0.016 |
|
|
10.1A-11A |
0.012 |
|
|
12.1A-13A |
0.010 |
|
|
14.1A-16A |
0.008 |
|
|
18.1A-20A |
0.006 |
|
|